Judge the guarantee on a model that is not the vendor's

The vendor of an air-cooled condenser or a dry-cooling tower supplies both its guarantee and the model that judges it. DraftSolver gives the owner a model of the whole plant that is not the vendor's: its validation record is public, and every rating carries the equations it came from and their uncertainty.

What DraftSolver does for plant owners and utilities

Owners and utilities, owner's engineers, performance teams and third-party test agencies.

  • Acceptance tests to ASME PTC 30.1On the A-frame condensers, a test's runs are corrected to the guarantee conditions with the Code's uncertainty, and the plant model is set beside the Code's method. A test can be planned before it is run.
  • The performance curves as builtThe curves a test is judged on, drawn from the plant model: back pressure against inlet air, one curve per steam flow, each as the Code's equation with its range and its largest deviation.
  • What the plant should deliverA rating at the day's weather and load gives what the plant should deliver, with its uncertainty band and what to know about the result, to set beside what it delivers.
  • Wind and start-upCrosswind and plume recirculation are in the one-dimensional model. The Transient simulation follows the plant through a start-up, a change of load or a change of weather.
  • A year of the site's weatherAn annual run rates the plant at every hour of a weather year: the heat rejected each month, and the hours above a back pressure.
  • A record that shows its workingEvery result names the equations that produced it, each with its source, its fitted range and its stated accuracy, and each run's datasheet lists them: a record that can be checked line by line in a dispute.
The results of a rating of an A-frame air-cooled condenser, Kröger's Example 8.1.4: heat transfer rate 19.63 MW, steam condensed 8.316 kg/s, back pressure 19.93 kPa, air mass flow 604.5 kg/s, followed by the findings on the result and a table of the example's published values beside the computed ones, within tolerance.
Figure 1. A rating's results: the plant's figures, then what to know about the result, graded by how much it matters, and on a worked example the published values beside the computed ones. From DraftSolver 0.1.0.

The systems it covers

Air-cooled condensers

Natural-draft towers

The plan that fits

Expert holds every system and every analysis, with the ASME PTC 30.1 curves and acceptance test, CFD and 2,000 credits a year. A utility with several sites or teams takes Enterprise: more seats, custom validation and priority support.

  • Expert

    Owner's engineers, performance teams and test agencies: acceptance tests, guarantees and disputes.

    • Rating, sweeps, design and annual runs
    • ASME PTC 30.1 curves and acceptance
    • The discretised transient
    • The Monte Carlo band
    • CFD
    • CFD lab
    • 2,000 CFD credits a year
    • Systems: Data-centre dry coolers, Mechanical draft and Natural draft

    Request early access

  • Enterprise

    Utilities, large EPCs and OEMs: more seats, custom validation and priority support.

    • Rating, sweeps, design and annual runs
    • ASME PTC 30.1 curves and acceptance
    • The discretised transient
    • The Monte Carlo band
    • CFD
    • CFD lab
    • Co-simulation
    • CFD credits, quoted with the order
    • Systems: Data-centre dry coolers, Mechanical draft and Natural draft

    Contact us