Consultants, OEMs and EPCs
Size it, bid it and hand over its curves from one case
A consultant or a bid engineer sizes a dry-cooling plant for a heat load and a site, compares the options, and hands over the curves the owner will test it against. DraftSolver works all of it on one case: a design, the sweeps behind a bid, a year of the site's weather, the performance curves and CFD of the same plant, each run with a datasheet.
What DraftSolver does for consultants, OEMs and EPCs
Design consultancies, and the bid engineers of OEMs and EPCs.
- DesignDesign fixes a target and solves for one dimension of the plant. The answer is applied to the setup in one step, and the design locus shows how the target moves with that dimension.
- The sweeps behind a bidA parametric sweep repeats the rating along one or more axes, such as the ambient temperature, with the uncertainty band at each point when it is asked for.
- The site's yearAn annual run rates the plant at every hour of the site's weather year, for the heat rejected each month and the fan energy over the year.
- Curves for the contractOn the A-frame condensers, the ASME PTC 30.1 performance curves of the plant as bid, each as the Code's equation with its range and its largest deviation.
- Wind in the one-dimensional modelCrosswind and plume recirculation are in the one-dimensional model, so layouts are compared under wind before any CFD is run.
- CFD of the plant as bidRun in CFD ports the rated plant to CFD as it stands. The CFD lab adds windbreak walls, the site's buildings and terrain as bodies from STL, and the wind's direction.
The systems it covers
Air-cooled condensers
- Air-cooled condenser, A-frame forced draft
Condenses turbine exhaust steam in A-frame bundles, with fans below pushing the air through them.
- Air-cooled condenser, A-frame induced draft
Condenses turbine exhaust steam in A-frame bundles, with fans above the apex drawing the air through them.
Dry coolers
- Dry cooler, plate-fin coil
Cools water or an antifreeze solution in plate-fin coils, with fans below pushing the air through them.
- Dry cooler, plate-fin coil, induced draft
Cools water or an antifreeze solution in plate-fin coils, with fans above drawing the air through them.
Air-cooled heat exchangers
- Air-cooled heat exchanger, forced draft
Cools a process fluid in horizontal finned-tube bundles, with fans below pushing the air through them.
- Air-cooled heat exchanger, induced draft
Cools a process fluid in horizontal finned-tube bundles, with fans above drawing the air through them.
Natural-draft towers
- Direct natural draft, vertical bundles
Condenses turbine exhaust steam in finned-tube bundles standing around the base of a natural-draft tower.
- Indirect dry cooling, natural draft, horizontal array
Cools a condenser's circulating water in bundles lying in the inlet of a natural-draft tower.
- Indirect dry cooling, natural draft, vertical bundles
Cools a condenser's circulating water in bundles standing around the inlet of a natural-draft tower.
What it was compared with
The worked examples of Kröger's book, which the app ships as complete cases. They are published calculations, not measurements; when one is run, the results page reports the agreement with the published values.
- Worked exampleKröger Example 7.3.1 closed on its own heat transfer rate: the loop returns his water temperature
- Worked exampleKröger Example 7.3.1Indirect natural-draft tower, horizontal array
- Worked exampleKröger Example 8.1.1Forced-draft air-cooled heat exchanger bay
- Worked exampleKröger Example 8.1.2Induced-draft air-cooled heat exchanger bay
- Worked exampleKröger Example 8.1.4A-frame air-cooled steam condenser
- Worked exampleKröger Example 8.3.1A forced-draft bank of six bays
- Worked exampleKröger Examples 8.3.2 and 8.4.2An eighteen-unit air-cooled condenser bank
- Worked exampleKröger Example 8.4.1Plume recirculation on a forced-draft bank
- Worked exampleKröger Example 9.2.1The same tower with its A-frames laid flat
- Worked exampleKröger Example 9.2.2The horizontal array under a 6 m/s crosswind
- Worked exampleKröger Example 9.3.1The six-bay bank under a 3 m/s crosswind
- Worked exampleKröger Example 9.3.2The six-bay bank under a 3 m/s wind along its axis
- Worked exampleNDDCS design pointDirect natural-draft tower, vertical bundles
The plan that fits
Pro holds one family of systems for rating, sweeps, design and annual runs, and Run in CFD is an add-on to it. Expert adds every system, the ASME PTC 30.1 curves, the Transient simulation and CFD. A large EPC or OEM takes Enterprise.
Pro
Consultancies and OEM or EPC bid engineers working on one family of systems.
- Rating, sweeps, design and annual runs
- Systems: one pack, chosen, and a second as an add-on
Expert
Owner's engineers, performance teams and test agencies: acceptance tests, guarantees and disputes.
- Rating, sweeps, design and annual runs
- ASME PTC 30.1 curves and acceptance
- The discretised transient
- The Monte Carlo band
- CFD
- CFD lab
- 2,000 CFD credits a year
- Systems: Data-centre dry coolers, Mechanical draft and Natural draft
Enterprise
Utilities, large EPCs and OEMs: more seats, custom validation and priority support.
- Rating, sweeps, design and annual runs
- ASME PTC 30.1 curves and acceptance
- The discretised transient
- The Monte Carlo band
- CFD
- CFD lab
- Co-simulation
- CFD credits, quoted with the order
- Systems: Data-centre dry coolers, Mechanical draft and Natural draft